詳細介紹

關於高效過濾器的更換周期方(fāng)麵的問題,很多潔淨室用戶都很關心,畢竟高(gāo)效過濾器決定著潔淨室的潔(jié)淨度能否達到標準,就在前方草莓秋葵菠萝蜜黄瓜榴莲视频也整理過相關方麵的問題:高效過濾器的更換標準

In the pharmaceutical industry, HEPA filters are used as terminal filters for the processing or filtration of air in production spaces. They are mandatory in sterile production, although they are sometimes also used in the manufacture of solid or semisolid dosage forms. Amongst the HEPA or high-efficiency particulate air filters are Filter Classes H13 to H14 (DIN 1822), the latter with a retention rate of 99.995%. But how often do they need to be changed?

在製藥行業,高效過濾器(HEPA)用於生產空間空氣的處理和過濾的終端過濾器。無菌生產要求強製(zhì)使用高效過濾器,而固(gù)體和(hé)半固體劑型的生產有時(shí)也會使用。H13至H14(DIN1822)是高效過濾器的(de)兩種,後(hòu)者截留率為99.995%。但多久必須更換一次(cì)呢?

One can frequently find internal company guidelines according to which the filters should be changed annually, regardless of monitoring results. Is that sensible? An exact number, meaning the maximum duration of use for HEPA filters in months, cannot be found in the relevant GMP guidelines. According to GMP, the filter has to be free of leaks. This is verified by qualification and regularly performed leak tests as per ISO 14644-3, which are mandatory for sterile facilities. According to the technical 參考:(www.ljinghua.com)interpretation of the Annex 1 (PIC/S PI 032-2), leak tests are to be performed every six months in A/B zones and every twelve months in C/D zones. The FDA Aseptic Guide demands a regular inspection. The requirements of Annex 1 can be applied here as well. Leaks may be repaired; those repaired areas may only take up 0.5% of the filter surface per filter.

製藥廠高效過濾器(qì)一般(bān)多久更換?

草莓秋葵菠萝蜜黄瓜榴莲视频經常看到在公司內部(bù)文件中,要求每(měi)年更換過濾(lǜ)器,而不管檢測(cè)結果如何。這是否合理?在相關的GMP指南中並沒有高(gāo)效過濾器(qì)可以使用(yòng)期限的具體數值(zhí)。根(gēn)據GMP的要求,過濾(lǜ)器不得有泄漏,這需要(yào)通過確認和定期執行ISO14644-3中的泄漏測試,無(wú)菌車間來說這是必須的。根據附錄1(PIC/S PI032-2)的技術詮釋,A/B級每6個月進行泄漏測試,C/D級則為12個月。FDA無菌指南要求進行定期檢查。附錄1的要求在這裏也適用。泄漏是可以修補(bǔ)的,但修補(bǔ)的麵積不能超過單個過(guò)濾器麵積的(de)0.5%。)

However, not only the integrity of the HEPA filter is relevant. The load of the filter (layer) and thus the pressure drop at the filter is also important. If the pressure drop at the filter rises, the energy demand of the ventilation system increases to maintain the necessary air change rates. This pressure drop at the filter can increase to the performance limits of the ventilation system. To protect the HEPA filters, preliminary filters are used - usually fine particulate air filters like F7 und F9 filters (EN779). Those have to be replaced regularly and protect the HEPA filters from clogging.

當(dāng)然,廣州靈(líng)潔淨化高效過濾器並不隻有(yǒu)完整性一件事情。過濾器(層)的負載以及上下遊壓差也很重要。如果過濾器(qì)上下遊壓差升高,則送排風係統(tǒng)的能量需求會增加,這(zhè)樣才能維持必須的換氣次數。這(zhè)樣的過(guò)濾器上下遊壓差可(kě)能會增加通風係統的性能限製。為了保護(hù)高效過濾器,就要使用(yòng)前端過濾器---通常是像F7和F9過濾器(EN779)這樣(yàng)的精細過濾器。這些過濾器(qì)必須(xū)定期更換以保護高效過濾器避免堵塞

From a practical viewpoint, one could say that the maximum duration of use depends directly on the pressure drop. Changing the filters only makes sense if the pressure drop gets too high for the performance of the ventilation system or if the cost of energy demand lies above the cost of a filter change. The filters do have to pass the leak tests (see above), of course. In practice, several companies do not use a filter for more than eight years. As mentioned before, though, this is not a legally binding value, but merely based on experience.

從實踐角度來看(kàn),草莓秋葵菠萝蜜黄瓜榴莲视频可(kě)以說最長使用期限直接取決於上下(xià)遊壓差。隻(zhī)有在上下遊壓差達(dá)到一定數值影響到(dào)通風係統的性能,或者是能量需求超(chāo)過過濾器更換成本時,過濾器更(gèng)換才有(yǒu)意義。但是,過濾器必須能通過泄漏測試(如上所述)。事實上,很多公(gōng)司並不會使用一(yī)個(gè)過濾器超過8年。正如前述,並沒有法規(guī)規定這樣的(de)值,這都隻是根(gēn)據(jù)經驗得來的。

靈潔高效過濾器更換問題

谘詢內容:老師您好(hǎo),小容量注射劑車間空調係(xì)統的高效過濾器必(bì)須定期更換嗎?如不定期更換,隻(zhī)在空調(diào)驗證(zhèng)時更換風(fēng)量不合格房(fáng)間高效和撿漏不合格高效可以嗎?

CFDA審核查驗中心回複:你(nǐ)好,更換高效過濾器根據空調驗證參考:時風量和撿漏是必須的,但同時也應製定出具體高效過濾器最長使用周期,故還(hái)是應該有定期的概念。同時必(bì)須定期進行過濾器(qì)完整性測試。

製藥廠高效過濾器一般多(duō)久更換?

潔淨區A級(jí)高效過(guò)濾器檢漏

谘詢內容:潔淨區A級高效過濾器檢(jiǎn)漏是否可以使用 塵埃粒子計數器 掃描檢漏,如果(guǒ)可以,那(nà)麽判斷無泄漏的標準是多少。

CFDA審核查驗中心(xīn)回複:靈潔高效過濾器檢(jiǎn)漏一般在非關鍵區域可以使用塵(chén)埃粒子計數器,但A級潔(jié)淨區高效過濾器不推薦使用塵埃粒子計(jì)數器掃描檢漏


本文網址:http://www.hrbpf.com/product/645.html

關鍵詞:藥廠高(gāo)效過濾器,製藥高效過濾器,潔淨室高效過濾器

最近(jìn)瀏覽:

在(zài)線(xiàn)留言
您的姓名:
您的電話:
留(liú)言內容:
聯係草莓秋葵菠萝蜜黄瓜榴莲视频

聯  係 人:龔經理

電      話:13710142110

傳      真:020-84550845

郵(yóu)      編(biān):510000

網      址:www.hrbpf.com

郵(yóu)      箱(xiāng):lingjie@gdlingjie.com 

地      址:廣東省廣州市番禺區石基鎮進盈工業園A區E座



二維碼

111111.png

Copyright 2018,廣州靈潔空氣淨化設備官方(fāng)網(wǎng)站版權所有   備案號:粵(yuè)ICP備12000047號-6   技術支持:廣州靈潔

  • 在線客服
  • 聯係電話
    13829746856
  • 在線留言
  • 手機網站
  • 在線谘詢
    歡迎給草莓秋葵菠萝蜜黄瓜榴莲视频留言
    請在此輸入留言內容,我(wǒ)們會盡快與您聯係。
    姓名
    聯係人
    電(diàn)話
    座機/手機號(hào)碼
    郵箱
    郵箱
    地址
    地址
    网站地图 草莓秋葵菠萝蜜黄瓜榴莲视频_榴莲视频下载_榴莲视频色版_榴莲app官网下载1.0.3