關於高效過濾器的更(gèng)換周期方麵的問題,很多潔(jié)淨室用戶都很關心,畢竟高效過濾器決定著潔淨室的潔淨度能否達到標準,就在(zài)前方草莓秋葵菠萝蜜黄瓜榴莲视频也(yě)整理過相關方麵的問題:高效(xiào)過濾器的更換標準
In the pharmaceutical industry, HEPA filters are used as terminal filters for the processing or filtration of air in production spaces. They are mandatory in sterile production, although they are sometimes also used in the manufacture of solid or semisolid dosage forms. Amongst the HEPA or high-efficiency particulate air filters are Filter Classes H13 to H14 (DIN 1822), the latter with a retention rate of 99.995%. But how often do they need to be changed?
在製藥行業,高效過濾器(qì)(HEPA)用於生產空間空氣的處理和過濾的終端過濾器。無菌生(shēng)產要求強製使用高效過濾器,而固體和半固體(tǐ)劑(jì)型的生產有(yǒu)時也會使用。H13至(zhì)H14(DIN1822)是高(gāo)效過濾器的兩種,後者截留率為99.995%。但多久必須更換一次呢?
One can frequently find internal company guidelines according to which the filters should be changed annually, regardless of monitoring results. Is that sensible? An exact number, meaning the maximum duration of use for HEPA filters in months, cannot be found in the relevant GMP guidelines. According to GMP, the filter has to be free of leaks. This is verified by qualification and regularly performed leak tests as per ISO 14644-3, which are mandatory for sterile facilities. According to the technical 參考:(www.ljinghua.com)interpretation of the Annex 1 (PIC/S PI 032-2), leak tests are to be performed every six months in A/B zones and every twelve months in C/D zones. The FDA Aseptic Guide demands a regular inspection. The requirements of Annex 1 can be applied here as well. Leaks may be repaired; those repaired areas may only take up 0.5% of the filter surface per filter.
製藥(yào)廠高效過濾器一般多久(jiǔ)更換?
草莓秋葵菠萝蜜黄瓜榴莲视频(men)經常看到在公司內部文件中,要求每年更換過濾器,而不管檢(jiǎn)測結果如何。這是否合理?在相關(guān)的GMP指南中並沒有高效過濾器可以(yǐ)使用期限的具體數值。根據GMP的要求,過濾器不得有泄漏,這需要通過(guò)確認和定期執(zhí)行ISO14644-3中的泄漏測(cè)試,無菌車間來說這(zhè)是(shì)必須的。根據附(fù)錄1(PIC/S PI032-2)的技術詮釋,A/B級每6個月進行(háng)泄(xiè)漏測試,C/D級則為12個月。FDA無菌指南(nán)要求進行定期檢查。附錄1的(de)要(yào)求在這裏也適用。泄(xiè)漏是(shì)可以修補(bǔ)的,但修補的麵積不能超過單個過濾器麵積的(de)0.5%。)
However, not only the integrity of the HEPA filter is relevant. The load of the filter (layer) and thus the pressure drop at the filter is also important. If the pressure drop at the filter rises, the energy demand of the ventilation system increases to maintain the necessary air change rates. This pressure drop at the filter can increase to the performance limits of the ventilation system. To protect the HEPA filters, preliminary filters are used - usually fine particulate air filters like F7 und F9 filters (EN779). Those have to be replaced regularly and protect the HEPA filters from clogging.
當然,廣州靈潔(jié)淨化高效過濾器並不隻有完整性一件(jiàn)事情(qíng)。過濾器(層)的負載以及上下遊(yóu)壓差也很(hěn)重要。如果過濾器上下遊壓差升(shēng)高,則送排風係統的能量需求(qiú)會增加,這樣才能(néng)維持必(bì)須的換氣次數(shù)。這樣的過濾器上下遊壓差可能會增加通風係統的性能限製(zhì)。為了(le)保護高效過濾器,就要使用前端過濾器(qì)---通常(cháng)是像F7和F9過濾器(EN779)這樣的精(jīng)細過濾器。這些過濾器必須定期更換(huàn)以保護高效過濾器避免堵塞
From a practical viewpoint, one could say that the maximum duration of use depends directly on the pressure drop. Changing the filters only makes sense if the pressure drop gets too high for the performance of the ventilation system or if the cost of energy demand lies above the cost of a filter change. The filters do have to pass the leak tests (see above), of course. In practice, several companies do not use a filter for more than eight years. As mentioned before, though, this is not a legally binding value, but merely based on experience.
從實踐(jiàn)角(jiǎo)度來看,我(wǒ)們可以(yǐ)說最長使用期限直接(jiē)取決於上下(xià)遊壓差。隻有在上(shàng)下遊壓差達到一定數值影響到通(tōng)風係統的性能,或(huò)者是能量需求超過過濾器更換成本時(shí),過濾器更換才有意義。但是,過濾器必(bì)須能通過泄漏測試(如上(shàng)所述)。事實上,很(hěn)多公司並(bìng)不會使用一個過濾器超過8年(nián)。正如前述,並(bìng)沒有法規規定這樣的(de)值,這都隻是根據經驗得來的。
靈潔高效過濾器更換(huàn)問題
谘詢內容:老師您好(hǎo),小容量注射劑車間空調係統(tǒng)的(de)高效過濾器必須定期更換嗎?如不定期更換,隻在空調驗證時更換風(fēng)量(liàng)不合格房間高效和撿漏不合格高效可以嗎?
CFDA審核查驗中心回複:你好,更換高效過濾器根據空調驗(yàn)證參考:時風量和撿漏是必須的,但同時(shí)也應製(zhì)定出具(jù)體高效過濾器最長使用周期,故還是應該有定期(qī)的概念。同時必須定期進行過濾器完整性測(cè)試。
製藥廠高效過濾器一般多久更換?
潔淨區A級高效(xiào)過濾器(qì)檢漏
谘詢內容:潔淨區(qū)A級高效過濾器檢漏是否可以使(shǐ)用 塵埃(āi)粒子計數器 掃描檢漏,如(rú)果可(kě)以,那麽判(pàn)斷無泄(xiè)漏的標(biāo)準是多少(shǎo)。
CFDA審核查驗中心回複:靈(líng)潔高效過濾器檢(jiǎn)漏一般在非關鍵(jiàn)區域可以使用(yòng)塵埃粒子計數器,但A級潔淨區高效過濾器不推薦使用塵埃粒子計數器掃描檢(jiǎn)漏