關(guān)於高效過(guò)濾器的更(gèng)換周期方麵的問題,很多潔淨室用戶都很關心,畢竟高效過濾器決定著潔淨室的潔淨度能否達到標準(zhǔn),就在(zài)前方草莓秋葵菠萝蜜黄瓜榴莲视频也整理過(guò)相關方麵的問題:高(gāo)效過濾器的更換標準

In the pharmaceutical industry, HEPA filters are used as terminal filters for the processing or filtration of air in production spaces. They are mandatory in sterile production, although they are sometimes also used in the manufacture of solid or semisolid dosage forms. Amongst the HEPA or high-efficiency particulate air filters are Filter Classes H13 to H14 (DIN 1822), the latter with a retention rate of 99.995%. But how often do they need to be changed?

在(zài)製藥行業(yè),高效過濾器(HEPA)用於生產空(kōng)間空氣的處理和過濾的終(zhōng)端過濾器。無菌生產要求(qiú)強製使(shǐ)用高效過濾器,而固體和半固體劑型(xíng)的生產有時(shí)也會(huì)使用。H13至H14(DIN1822)是高效過濾器的兩種,後者截留率為99.995%。但(dàn)多久(jiǔ)必(bì)須更換一次呢?

One can frequently find internal company guidelines according to which the filters should be changed annually, regardless of monitoring results. Is that sensible? An exact number, meaning the maximum duration of use for HEPA filters in months, cannot be found in the relevant GMP guidelines. According to GMP, the filter has to be free of leaks. This is verified by qualification and regularly performed leak tests as per ISO 14644-3, which are mandatory for sterile facilities. According to the technical 參考:(www.ljinghua.com)interpretation of the Annex 1 (PIC/S PI 032-2), leak tests are to be performed every six months in A/B zones and every twelve months in C/D zones. The FDA Aseptic Guide demands a regular inspection. The requirements of Annex 1 can be applied here as well. Leaks may be repaired; those repaired areas may only take up 0.5% of the filter surface per filter.

製藥廠高效過濾器一般多久更換?

草莓秋葵菠萝蜜黄瓜榴莲视频經常看到(dào)在公司內部文件中,要求每年更換過濾器,而不管檢測結果如何。這是(shì)否合理?在相關的GMP指南中(zhōng)並沒有高(gāo)效過(guò)濾器可以使用期限的具體(tǐ)數值。根據GMP的要(yào)求,過濾器不得有泄漏,這需要通(tōng)過確認和定期執行ISO14644-3中的泄漏測(cè)試,無(wú)菌車間來說這是必須的。根據附錄1(PIC/S PI032-2)的技術詮釋,A/B級每6個月進(jìn)行泄(xiè)漏測試,C/D級(jí)則為12個月。FDA無菌指南要求進行(háng)定期檢查。附錄1的要求在這裏(lǐ)也適用。泄漏是可以修補的,但修補的麵(miàn)積不能超過(guò)單個過(guò)濾器麵積的0.5%。)

However, not only the integrity of the HEPA filter is relevant. The load of the filter (layer) and thus the pressure drop at the filter is also important. If the pressure drop at the filter rises, the energy demand of the ventilation system increases to maintain the necessary air change rates. This pressure drop at the filter can increase to the performance limits of the ventilation system. To protect the HEPA filters, preliminary filters are used - usually fine particulate air filters like F7 und F9 filters (EN779). Those have to be replaced regularly and protect the HEPA filters from clogging.

當然,廣州靈潔淨化高效過濾器並不隻有(yǒu)完整性一件事情。過濾器(qì)(層(céng))的負載以及上(shàng)下遊壓差(chà)也很重要。如(rú)果過濾器上下遊(yóu)壓差升高,則送排風係統的能量需求會增加,這樣才能(néng)維持必(bì)須的換氣次數。這樣的過濾器上下遊壓差可能會增加通風係統的性能限製。為了保(bǎo)護高效過濾器,就要使用前端(duān)過濾器---通常是像F7和F9過濾器(EN779)這樣的(de)精細過濾(lǜ)器。這些過濾器必須定期更換(huàn)以保護高效過濾器避免堵塞

From a practical viewpoint, one could say that the maximum duration of use depends directly on the pressure drop. Changing the filters only makes sense if the pressure drop gets too high for the performance of the ventilation system or if the cost of energy demand lies above the cost of a filter change. The filters do have to pass the leak tests (see above), of course. In practice, several companies do not use a filter for more than eight years. As mentioned before, though, this is not a legally binding value, but merely based on experience.

從實踐角度來看(kàn),草莓秋葵菠萝蜜黄瓜榴莲视频可以說最長使用期限直接取決於上下(xià)遊壓差。隻有在上下遊壓差達到一定數值(zhí)影響到通風(fēng)係統的性能,或者是能量需求超過過濾器更換成本時,過濾器更換才有意義。但是(shì),過濾器必須能通過泄漏測試(如(rú)上所述)。事實上,很多公司並不會使用(yòng)一個過濾(lǜ)器超過8年。正如(rú)前述,並沒有法規規定(dìng)這樣的值,這都隻是根據經驗得來的。

靈潔高效(xiào)過(guò)濾器更(gèng)換問題

谘詢內容:老師您好,小容量注射劑車間空調係統(tǒng)的高效過濾器必須定(dìng)期更換嗎?如不定期更換,隻在空調驗證時更換風量不合格房間高效和撿漏不合格高效可以嗎(ma)?

CFDA審核(hé)查驗中心回複:你好,更(gèng)換高效過濾器根據空調驗證參考:時風量和撿漏是必須的,但同時也(yě)應製定出具體(tǐ)高效過濾器最長使用周期,故還是應該有(yǒu)定期的概念(niàn)。同時必須定期進行過濾器完整性測試(shì)。

製藥廠高效過濾器一般多久更換?

潔淨區A級高效過濾器檢漏

谘詢內容:潔淨區A級高效過濾器檢漏是(shì)否可以使用(yòng) 塵埃粒子計數器(qì) 掃描檢漏,如果可以,那麽判斷無泄漏的標準是多少。

CFDA審核查驗中心回複:靈潔高效過濾器檢漏一般(bān)在非關鍵區(qū)域可以使用塵埃粒子計(jì)數器,但A級潔淨區高效過濾器(qì)不推薦使用塵埃粒子計(jì)數器掃(sǎo)描檢漏


本文網址:http://www.hrbpf.com/product/645.html

關鍵詞:藥廠高效過濾器,製藥(yào)高效過濾器,潔淨室高效過濾器

最近瀏(liú)覽:

在線留言
您的姓名:
您的電話(huà):
留(liú)言內容:
聯係草莓秋葵菠萝蜜黄瓜榴莲视频

聯  係 人:龔經(jīng)理

電      話:13710142110

傳      真:020-84550845

郵      編:510000

網      址:www.hrbpf.com

郵      箱:lingjie@gdlingjie.com 

地      址:廣東省廣州市番禺區石基鎮進盈工業園(yuán)A區E座



二維碼

111111.png

Copyright 2018,廣州靈潔空氣淨化設備官方網站版(bǎn)權所有   備案號:粵ICP備12000047號-6   技術(shù)支持:廣州靈潔

  • 在線(xiàn)客服
  • 在線留言
  • 手機網站
  • 在線谘詢
    歡迎給草莓秋葵菠萝蜜黄瓜榴莲视频留言
    請在此輸入留言內容,草莓秋葵菠萝蜜黄瓜榴莲视频會盡快(kuài)與您聯係。
    姓名
    聯係人
    電話
    座機/手機號碼
    郵箱
    郵箱
    地址
    地址
    网站地图 草莓秋葵菠萝蜜黄瓜榴莲视频_榴莲视频下载_榴莲视频色版_榴莲app官网下载1.0.3