初效過濾器、中效過濾器、高效過濾器、淨化設(shè)備專業生產廠家(國家技術企業)歡迎您!

服務熱線:4008-727374

空氣過濾器

本溪製藥廠(chǎng)高效過濾器

  • 所屬分類(lèi):本溪高效過(guò)濾器

  • 點擊次數:
  • 發布日期:2020/11/26
  • 在(zài)線詢價(jià)
詳細介(jiè)紹

關於高效過濾(lǜ)器的更換周期方麵的問題,很多潔淨室用戶都很關心,畢(bì)竟高效過濾器決定著潔淨室的(de)潔淨度能否(fǒu)達到標準,就在前方草莓秋葵菠萝蜜黄瓜榴莲视频也整理過相關方麵的問題:高(gāo)效過濾器的更換標(biāo)準

In the pharmaceutical industry, HEPA filters are used as terminal filters for the processing or filtration of air in production spaces. They are mandatory in sterile production, although they are sometimes also used in the manufacture of solid or semisolid dosage forms. Amongst the HEPA or high-efficiency particulate air filters are Filter Classes H13 to H14 (DIN 1822), the latter with a retention rate of 99.995%. But how often do they need to be changed?

在製藥行業,高效過濾器(HEPA)用於生產空(kōng)間空氣的處理和(hé)過濾的終端過濾器。無菌生(shēng)產要求(qiú)強製使用高效過濾器,而固體和半固(gù)體劑型的生產有時也會使用。H13至H14(DIN1822)是高效過濾器的兩種,後者(zhě)截留率為99.995%。但(dàn)多久必須更換(huàn)一次(cì)呢?

One can frequently find internal company guidelines according to which the filters should be changed annually, regardless of monitoring results. Is that sensible? An exact number, meaning the maximum duration of use for HEPA filters in months, cannot be found in the relevant GMP guidelines. According to GMP, the filter has to be free of leaks. This is verified by qualification and regularly performed leak tests as per ISO 14644-3, which are mandatory for sterile facilities. According to the technical 參考:(www.ljinghua.com)interpretation of the Annex 1 (PIC/S PI 032-2), leak tests are to be performed every six months in A/B zones and every twelve months in C/D zones. The FDA Aseptic Guide demands a regular inspection. The requirements of Annex 1 can be applied here as well. Leaks may be repaired; those repaired areas may only take up 0.5% of the filter surface per filter.

製藥廠高效過濾(lǜ)器一般多久更換?

草莓秋葵菠萝蜜黄瓜榴莲视频(men)經常看到在公司內部文件中,要求每年更換過濾器,而不(bú)管(guǎn)檢測結果如何。這是否合理?在相關的GMP指南中並沒有高效過濾器可以使用期(qī)限的具體數值。根據(jù)GMP的要求,過濾器不(bú)得有泄漏,這需要通過確認(rèn)和定期執行ISO14644-3中的泄漏測試,無菌車間來(lái)說這是必須的。根據附錄1(PIC/S PI032-2)的技術詮釋,A/B級每6個月進行泄漏測試,C/D級則為12個月。FDA無菌指南要求進行定期檢查。附錄1的要(yào)求在這(zhè)裏也適用(yòng)。泄漏(lòu)是可以修補的,但修補的(de)麵積不能超過單個過濾器麵積的0.5%。)

However, not only the integrity of the HEPA filter is relevant. The load of the filter (layer) and thus the pressure drop at the filter is also important. If the pressure drop at the filter rises, the energy demand of the ventilation system increases to maintain the necessary air change rates. This pressure drop at the filter can increase to the performance limits of the ventilation system. To protect the HEPA filters, preliminary filters are used - usually fine particulate air filters like F7 und F9 filters (EN779). Those have to be replaced regularly and protect the HEPA filters from clogging.

當然,廣州靈潔淨化高效過濾器並不隻有完整性一件事情。過濾器(層)的負載以及上下遊壓(yā)差也很重要。如果過濾(lǜ)器上下遊壓差升高,則送排風係統的能量需求會增加,這(zhè)樣才能(néng)維持必須的換氣(qì)次數。這樣的過濾(lǜ)器上下遊壓差可能會增加通風係統的性能限製。為了保護高效過濾(lǜ)器,就要使用前端過濾器---通常是像F7和F9過(guò)濾器(EN779)這樣的精細過濾器。這些過濾器必須定期更換以保護高效過濾器避免堵塞

From a practical viewpoint, one could say that the maximum duration of use depends directly on the pressure drop. Changing the filters only makes sense if the pressure drop gets too high for the performance of the ventilation system or if the cost of energy demand lies above the cost of a filter change. The filters do have to pass the leak tests (see above), of course. In practice, several companies do not use a filter for more than eight years. As mentioned before, though, this is not a legally binding value, but merely based on experience.

從實踐角度來看,草莓秋葵菠萝蜜黄瓜榴莲视频可以說最長使用期限直接取決於上下遊壓差。隻有在上下遊壓差達到一定數值影響到(dào)通風係統的性能,或者是(shì)能量需(xū)求超過過濾器更換成本時,過濾(lǜ)器更換才有意義。但是,過濾器必須能通過(guò)泄漏測試(shì)(如上所述)。事實(shí)上,很(hěn)多公司並不(bú)會使用一個過濾(lǜ)器超過(guò)8年。正如前述,並(bìng)沒(méi)有法規規定這樣的值,這都隻(zhī)是根據經驗得來的。

靈潔高效過濾器更換問題

谘詢內容:老師您好,小容量注射劑車間空調係統的高效過濾器必(bì)須定期更換嗎?如不定期更換,隻在空調驗證(zhèng)時更換風量不合格房間高效和撿漏不(bú)合格高效可以(yǐ)嗎?

CFDA審核查驗中心回複:你(nǐ)好,更換(huàn)高效過濾器(qì)根據空調驗證參考:時風量和撿漏是必須的,但同時(shí)也應製定出具體高效過濾器最長使用周(zhōu)期,故還是應該有定(dìng)期的概念。同時必(bì)須定期進行(háng)過濾器完整性測(cè)試。

製藥廠高效過濾器(qì)一般(bān)多久更換?

潔(jié)淨區A級高效過濾器檢漏

谘詢內(nèi)容:潔淨(jìng)區A級高效過濾器檢漏是否可以(yǐ)使用 塵埃粒子計數器 掃描檢(jiǎn)漏,如(rú)果可以,那麽判斷無泄漏的標準是多少。

CFDA審核查驗中心回複:靈潔高(gāo)效過濾(lǜ)器檢漏一般在非關鍵區域可以使用塵埃粒(lì)子計數器,但A級潔淨(jìng)區高效過濾器不推薦使用塵埃粒子計數器掃描檢漏(lòu)


本文網址:http://www.hrbpf.com/product/645.html

關鍵詞:藥廠高(gāo)效過(guò)濾器,製藥高效(xiào)過濾器,潔淨室高效過濾(lǜ)器

最近瀏覽:

在線留言
您的姓名:
您的電話:
留言內容:
聯係我(wǒ)們

聯  係 人:龔經理

電      話:13710142110

傳      真:020-84550845

郵      編(biān):510000

網      址(zhǐ):www.hrbpf.com

郵      箱:lingjie@gdlingjie.com 

地      址:廣東省廣州市番禺區石基鎮進盈工業園A區E座



二維碼

111111.png

Copyright 2018,廣(guǎng)州靈(líng)潔空氣淨化設備官方網站版權所(suǒ)有   備案號:粵ICP備12000047號-6   技術支持:廣州靈(líng)潔

  • 在線客服
  • 在線留言
  • 手機網站
  • 在線谘(zī)詢(xún)
    歡迎給草莓秋葵菠萝蜜黄瓜榴莲视频留(liú)言
    請在此輸入留(liú)言內容,草莓秋葵菠萝蜜黄瓜榴莲视频會(huì)盡快與您聯係。
    姓名
    聯係人
    電(diàn)話
    座機/手機號(hào)碼
    郵箱(xiāng)
    郵箱
    地址
    地址(zhǐ)
    网站地图 草莓秋葵菠萝蜜黄瓜榴莲视频_榴莲视频下载_榴莲视频色版_榴莲app官网下载1.0.3